Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

18 May 2007

Low-dose protocol for head CT in monitoring hydrocephalus in children

Krzysztof Rybka, Maria Anna Staniszewska, Tadeusz Biegański

Med Sci Monit 2007; 13(1): 147-151 :: ID: 482436

Abstract

Background: Children with hydropcephalus and increased intracranial pressure are treated with ventricular shunts. Multiple head CT is used to assess shunt malfunction and changes in ventricular size (volume). Because of the naturally high contrast of the head structures in CT imaging, a low-dose protocol for hydrocephalic pediatric patients was proposed. The aim of the study was to assess the implemented protocol in categories of radiation risk to the patients.
Material and Methods: Head CT examinations were performed using the fourth-generation single-slice scanner PQ-2000 (Picker). Exposure parameters of the routine head procedure stored in the scanner software were the starting point for the investigation. The acceptable ranges of the modified parameters were found on the basis of earlier published results. The effect of the new protocol on image quality was tested using a CATPHAN phantom. The organ doses were evaluated experimentally. The clinical images were evaluated by two experienced and independent radiologists. Results: Head CT examinations were performed in 380 children with hydrocephalus during a 10-year period at the Department of Diagnostic Imaging Polish Mother’s Memorial Hospital. Until 2005 these children were examined according to the routine protocol of the scanner, i.e. 10 mm contiguous axial, 120 kVp, and 225 mAs. Then the protocol was modified to 10 mm contiguous axial, 100 kVp, and 150 mAs. Reductions in patient doses to 70% were found while the clinical images maintained sufficient diagnostic value. Conclusions: The low-dose protocol for head CT can be recommended for the monitoring of pediatric hydrocephalus patients.

Keywords: Adolescent, Child, Child, Preschool, Head - radiography, Hydrocephalus - therapy, Infant, Newborn, Intracranial Hypertension - radiography, Radiation Dosage, Tomography, X-Ray Computed - methods, Ventriculoperitoneal Shunt

Add Comment 0 Comments

Editorial

01 June 2025 : Editorial  

Editorial: Harmonization and Publication of the 2025 Updates of the CONSORT and SPIRIT Statements for Clinical Trials

Dinah V. Parums

DOI: 10.12659/MSM.949923

Med Sci Monit 2025; 31:e949923

0:00

In Press

Clinical Research  

Biomarker Discovery in Childhood Asthma: A Pilot Study of Serum Metabolite Analysis for IgE-Dependent Allergy

Med Sci Monit In Press; DOI: 10.12659/MSM.948478  

Review article  

Antitumor Alkaloids in Tibetan Corydalis: Chemical Diversity and Pharmacological Insights

Med Sci Monit In Press; DOI: 10.12659/MSM.947268  

Clinical Research  

Differentiating Between Methylphenidate Use and Misuse: Clinical Insights From University Students and Acad...

Med Sci Monit In Press; DOI: 10.12659/MSM.948984  

Clinical Research  

Six-Year Outcomes of CABG vs PCI in Diabetic Patients with Multivessel Coronary Disease

Med Sci Monit In Press; DOI: 10.12659/MSM.948348  

Most Viewed Current Articles

17 Jan 2024 : Review article   9,080,994

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

16 May 2023 : Clinical Research   704,112

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

01 Mar 2024 : Editorial   32,983

Editorial: First Regulatory Approvals for CRISPR-Cas9 Therapeutic Gene Editing for Sickle Cell Disease and ...

DOI :10.12659/MSM.944204

Med Sci Monit 2024; 30:e944204

0:00

28 Jan 2024 : Review article   27,378

A Review of IgA Vasculitis (Henoch-Schönlein Purpura) Past, Present, and Future

DOI :10.12659/MSM.943912

Med Sci Monit 2024; 30:e943912

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750